Toolkit / Neuromodulation
ECT stimulus dose calculator (titration, age-based, half-age)
Work out the treatment stimulus for each electrode placement: from the seizure threshold found at titration (the preferred method), or with the age-based and half-age methods. Shows the dose in millicoulombs and as a Thymatron percentage, and converts stimulus parameters into charge and energy.
The same threshold at other multiples
Enter a seizure threshold to compare multiples.
| Multiple | Usual for | Charge | Thymatron % |
|---|
Usual treatment dose
| Right unilateral | 6× threshold or more (brief pulse); 2.5× is less effective |
| RUL ultrabrief | Usually 6× threshold |
| Bitemporal | 1.5–2.5× threshold (1.5× has less cognitive risk) |
| Bifrontal | Usually 1–1.5× threshold |
Age-based settings (Thymatron)
| Age 20 | Age method (unilateral) 20% = 101 mC · Half-age (bitemporal) 10% = 50 mC |
| Age 30 | Age method (unilateral) 30% = 151 mC · Half-age (bitemporal) 15% = 76 mC |
| Age 40 | Age method (unilateral) 40% = 202 mC · Half-age (bitemporal) 20% = 101 mC |
| Age 50 | Age method (unilateral) 50% = 252 mC · Half-age (bitemporal) 25% = 126 mC |
| Age 60 | Age method (unilateral) 60% = 302 mC · Half-age (bitemporal) 30% = 151 mC |
| Age 70 | Age method (unilateral) 70% = 353 mC · Half-age (bitemporal) 35% = 176 mC |
| Age 80 | Age method (unilateral) 80% = 403 mC · Half-age (bitemporal) 40% = 202 mC |
Notes
- Titration (empirical dosing) is the preferred way to set the dose for every placement: at the first session, stimulate from a low dose and step up, 20–30 seconds apart, until an adequate generalised seizure occurs. That charge is the seizure threshold. Usually no more than 3–4 stimulations are given under one anaesthetic. Use your unit’s titration schedule.
- Treatment dose as a multiple of the threshold (NVvP 2021, based on Sackeim 2000 and later trials): right unilateral, 6× threshold or more (2.5× is less effective); bitemporal, 1.5–2.5× (starting at 1.5× carries less cognitive risk); bifrontal, usually 1–1.5×. Ultrabrief right unilateral ECT is also usually given at 6× threshold, but may need more sessions.
- Age-based method (right or left unilateral): Thymatron setting in % = age in years, so dose = age × 5.04 mC. Half-age method (bitemporal): % = half the age (Petrides and Fink 1996). Useful when sub-convulsive stimulation must be avoided, but less precise than titration because thresholds vary widely between people.
- Fixed high doses for everyone are discouraged for routine use because of greater cognitive side effects.
- The seizure threshold often rises during a course. If seizures become short or poor in quality, or the patient is not improving, raise the dose to keep the intended multiple, or re-titrate. In continuation or maintenance ECT, start from the last dose that gave an adequate seizure.
- Many things raise the threshold and shorten seizures: older age, male sex, bitemporal versus unilateral differences, high anaesthetic doses (especially propofol), benzodiazepines, anticonvulsants (including valproate and lamotrigine), and previous ECT. Many lower it: caffeine, theophylline, hyperventilation, and a longer gap since the last session.
- Charge (mC) = current (A) × pulse width (ms) × frequency (Hz) × train duration (s), multiplied by 2 when the frequency counts bidirectional pulse pairs (as MECTA and Thymatron do). Energy (J) ≈ charge (C) × current (A) × dynamic impedance (Ω); devices show energy at an assumed impedance (220 Ω for the Thymatron). Charge, not energy, is the preferred measure of dose.
- In India, the Mental Healthcare Act 2017 (section 95) allows ECT only with muscle relaxant and anaesthesia (modified ECT); for minors it needs guardian consent and Mental Health Review Board permission.
References
- Nederlandse Vereniging voor Psychiatrie (NVvP). Richtlijn Elektroconvulsietherapie (ECT), module “Doseringsmethode en gebruikte dosis bij ECT”. 2021. richtlijnendatabase.nl.
- Ferrier IN, Waite J, eds. The ECT Handbook. 4th ed. Royal College of Psychiatrists / Cambridge University Press; 2019.
- American Psychiatric Association. The Practice of Electroconvulsive Therapy: Recommendations for Treatment, Training, and Privileging. 2nd ed. APA; 2001.
- Petrides G, Fink M. The “half-age” stimulation strategy for ECT dosing. Convuls Ther. 1996;12(3):138–146.
- Abrams R. Electroconvulsive Therapy. 4th ed. Oxford University Press; 2002 (age-based dosing).
- Sackeim HA, Prudic J, Devanand DP, et al. A prospective, randomized, double-blind comparison of bilateral and right unilateral electroconvulsive therapy at different stimulus intensities. Arch Gen Psychiatry. 2000;57(5):425–434.
- Sackeim HA, Prudic J, Nobler MS, et al. Effects of pulse width and electrode placement on the efficacy and cognitive effects of electroconvulsive therapy. Brain Stimul. 2008;1(2):71–83.
- Kellner CH, Knapp R, Husain MM, et al. Bifrontal, bitemporal and right unilateral electrode placement in ECT: randomised trial. Br J Psychiatry. 2010;196(3):226–234.
- Kolshus E, Jelovac A, McLoughlin DM. Bitemporal v. high-dose right unilateral electroconvulsive therapy for depression: a systematic review and meta-analysis of randomized controlled trials. Psychol Med. 2017;47(3):518–530.
- Peterchev AV, Rosa MA, Deng ZD, Prudic J, Lisanby SH. Electroconvulsive therapy stimulus parameters: rethinking dosage. J ECT. 2010;26(3):159–174.
An educational aid for clinicians, not a substitute for clinical judgement. Follow your ECT unit’s protocol and the device manufacturer’s instructions; the treating team decides the dose. Nothing you enter on this page is stored or sent.
Spotted an error in this calculator?
Usual treatment dose
| Right unilateral | 6× threshold or more (brief pulse); 2.5× is less effective |
| RUL ultrabrief | Usually 6× threshold |
| Bitemporal | 1.5–2.5× threshold |
| Bifrontal | Usually 1–1.5× threshold |
| Age method | Thymatron % = age (unilateral) |
| Half-age | Thymatron % = age ÷ 2 (bitemporal) |
Notes
- Titration (empirical dosing) is the preferred way to set the dose for every placement: at the first session, stimulate from a low dose and step up, 20–30 seconds apart, until an adequate generalised seizure occurs. That charge is the seizure threshold. Usually no more than 3–4 stimulations are given under one anaesthetic. Use your unit’s titration schedule.
- Treatment dose as a multiple of the threshold (NVvP 2021, based on Sackeim 2000 and later trials): right unilateral, 6× threshold or more (2.5× is less effective); bitemporal, 1.5–2.5× (starting at 1.5× carries less cognitive risk); bifrontal, usually 1–1.5×. Ultrabrief right unilateral ECT is also usually given at 6× threshold, but may need more sessions.
- Age-based method (right or left unilateral): Thymatron setting in % = age in years, so dose = age × 5.04 mC. Half-age method (bitemporal): % = half the age (Petrides and Fink 1996). Useful when sub-convulsive stimulation must be avoided, but less precise than titration because thresholds vary widely between people.
- Fixed high doses for everyone are discouraged for routine use because of greater cognitive side effects.
- The seizure threshold often rises during a course. If seizures become short or poor in quality, or the patient is not improving, raise the dose to keep the intended multiple, or re-titrate. In continuation or maintenance ECT, start from the last dose that gave an adequate seizure.
- Many things raise the threshold and shorten seizures: older age, male sex, bitemporal versus unilateral differences, high anaesthetic doses (especially propofol), benzodiazepines, anticonvulsants (including valproate and lamotrigine), and previous ECT. Many lower it: caffeine, theophylline, hyperventilation, and a longer gap since the last session.
- Charge (mC) = current (A) × pulse width (ms) × frequency (Hz) × train duration (s), multiplied by 2 when the frequency counts bidirectional pulse pairs (as MECTA and Thymatron do). Energy (J) ≈ charge (C) × current (A) × dynamic impedance (Ω); devices show energy at an assumed impedance (220 Ω for the Thymatron). Charge, not energy, is the preferred measure of dose.
- In India, the Mental Healthcare Act 2017 (section 95) allows ECT only with muscle relaxant and anaesthesia (modified ECT); for minors it needs guardian consent and Mental Health Review Board permission.
References
- Nederlandse Vereniging voor Psychiatrie (NVvP). Richtlijn Elektroconvulsietherapie (ECT), module “Doseringsmethode en gebruikte dosis bij ECT”. 2021. richtlijnendatabase.nl.
- Ferrier IN, Waite J, eds. The ECT Handbook. 4th ed. Royal College of Psychiatrists / Cambridge University Press; 2019.
- American Psychiatric Association. The Practice of Electroconvulsive Therapy: Recommendations for Treatment, Training, and Privileging. 2nd ed. APA; 2001.
- Petrides G, Fink M. The “half-age” stimulation strategy for ECT dosing. Convuls Ther. 1996;12(3):138–146.
- Abrams R. Electroconvulsive Therapy. 4th ed. Oxford University Press; 2002 (age-based dosing).
- Sackeim HA, Prudic J, Devanand DP, et al. A prospective, randomized, double-blind comparison of bilateral and right unilateral electroconvulsive therapy at different stimulus intensities. Arch Gen Psychiatry. 2000;57(5):425–434.
- Sackeim HA, Prudic J, Nobler MS, et al. Effects of pulse width and electrode placement on the efficacy and cognitive effects of electroconvulsive therapy. Brain Stimul. 2008;1(2):71–83.
- Kellner CH, Knapp R, Husain MM, et al. Bifrontal, bitemporal and right unilateral electrode placement in ECT: randomised trial. Br J Psychiatry. 2010;196(3):226–234.
- Kolshus E, Jelovac A, McLoughlin DM. Bitemporal v. high-dose right unilateral electroconvulsive therapy for depression: a systematic review and meta-analysis of randomized controlled trials. Psychol Med. 2017;47(3):518–530.
- Peterchev AV, Rosa MA, Deng ZD, Prudic J, Lisanby SH. Electroconvulsive therapy stimulus parameters: rethinking dosage. J ECT. 2010;26(3):159–174.
This is an educational aid for clinicians, not a substitute for clinical judgement. Scores and calculations support, but never replace, a full assessment. All entries were made by the user; the website does not verify them and accepts no responsibility for decisions based on them. Nothing entered on the website is stored or sent.